Search
Male and female TCCS Plus Pro simulators

PCCS Pro

Level Up the Realism. Turn On the Intensity.

National Guard training simulation featuring advanced medical equipment

PCCS Pro Simulator

PCCS Pro is the world’s first fully modular, ultra-lifelike, trauma care simulator for prolonged casualty care training

PCCS Pro is the closest you can get to treating injuries in remote, high-stress locations without actually being there.

  • Meets all 13 PCCC guidelines for casualty management
  • Fully modular – interchangeable limbs and wounds
  • Greater fidelity and advanced physiology
  • 100% anatomically correct (female and male models)
  • 10 hours + battery life
  • More complex training scenarios
  • Ruggedized for indoor and outdoor environments
  • African-American, Asian, Caucasian and Hispanic Skin Tones

Modularity.
The Name of The Game

The PCCS Pro from Operative Experience is a revolutionary, fully modular trauma care simulator featuring groundbreaking, on-the-fly interchangeable wounds from a polytrauma patient to a medical patient, and featuring advanced physiology and conditions, drug support, fully-integrated patient monitoring, and all-new software capabilities and scenarios.

With PCCS Pro’s interchangeable wound capability, each simulator can be quickly and easily modified to support a uniquely diverse range of emergency scenarios and training possibilities.

Male TCCS Plus Pro simulator with wounds

Wound Configurations

 

Learn more about each of our standard wound configuration

Wounds and Ethnicity

Choose from up to six standard ultra-realistic wound configurations, including gunshot wounds, amputations, open and closed fractures, and inguinal wounds featuring multiple and independent pulsatile arterial bleeding and venous bleeding

Each simulator is available in a choice of African American, Asian, Caucasian, and Hispanic skin tones.

Modular Wounds and Software Upgrades

In addition to the standard wound configurations, TCCS Pro allows you to customize your training scenarios with 16 different interchangeable plug-and-play trauma limbs and on-the-fly moulage wounds, featuring TCCS Pro Smart Limbs™, designed to recognize and adjust to each wound configuration automatically. Sim Pro app-based software is fully upgradable for additional scenarios, patient conditions, drug support, real-world patient monitor options and more.

TCCS Plus simulator monitor screen

Available Add-Ons

 

Want to know more about our available add-ons?

Gold Standard Support and Maintenance

Operative Experience offers an extensive optional support and maintenance program to provide help when you need it and to ensure you get the most out of your simulators including:

  • Phone and online customer support
  • Remote and on-site maintenance
  • Annual on-site preventative maintenance
  • Installation and training
  • Ongoing remote and on-site training
  • Free shipping and loaner simulator during maintenance
  • Free software updates


See how OEI has created a Customer-Centric Service Process.

Want to Know More

Technical Specifications for the PCCS PRO

System and Clinical Capabilities

Features Technical Details
Modularity & Hardware
  • Interchangeable Plug-and-Play Limbs
  • Compatible for Add-On Moulage Wounds
  • Easy-to-use Instructor Tablet

Software Platform

  • OEI SIM Pro Software
    (iPadOS, Android and Mac/PC)
  • Compatible for OEI SIM Pro Software Upgrades
  • Smart Limb™ Recognition
Patient Monitoring
  • Integrated Patient Monitoring
    (NiBP, ABP, CVP, Plethysmograph, Capnography, (extensive) ECGs & 12-lead ECGs, SpO2, Temperature)
Clinical Capabilities
  • Clinical and Trauma Scenarios
  • Drug Support
    (TCCC, Fluids, AMLS and ALS)
Reporting & Diagnostics
  • Maintain Simulation Logs
  • Complete Self-Diagnostics
  • Hourmeter
  • Virtual DD 1380/TCCC Patient Assessment Card

Mannequin and Hardware Specifications

Features Technical Details
Construction & Mobility
  • Full-Body, Wireless, and Tetherless Simulator
  • Fully-Articulated Limbs
Durability & Environment
  • Ruggedized and Water-Resistant for Indoor and Outdoor Environments
  • Patient Decontamination Capable
Weight & Realism
  • Realistic and Lifelike Weight 
  • Male: 185 lbs
  • Female: 135 lbs
Advanced Features
  • Hypothermia Prevention/Active Heating Blanket

Power System
  • 10+ Hours Battery Life
  • AC Input: 100-240 VAC, 50-60 Hz
  • AC Output: 24 VDC 6A 120 W

Training Competencies

Features Technical Details
Tactical Operations
  • Establish Perimeter
  • Perform Patient Extraction
Patient Assessment
  • Perform First Impression Assessment
  • Perform Primary Assessment
Care Management
  • Triage Patients

Airway Management

Features Technical Details
Complications & Obstructions
  • Difficult Airway with Airway Complication: Tongue and Pharynx Swelling
  • Perform Foreign Body Removal from Oral Cavity
  • Perform Suction of the Nasal and Oral Pharyngeal Airways
Basic Maneuvers & Assessment
  • Head Tilt, Chin Lift & Jaw Thrust Maneuvers
  • Assessment of Oral and Nasal Airways
  • Perform Mouth-Mouth Respirations With or Without Barrier Device
  • Placement in the Recovery Position
Advanced Intubation & Surgical
  • Realistic Airway – Intubation Capable
  • Supports Nasal/Oral Pharyngeal Airway Devices, Supraglottic Airway, Endotracheal & Nasal Intubation, and Blind Intubation
  • Perform Needle & Surgical Cricothyrotomy

Circulation Specifications

Features Technical Details
Vitals & Assessment
  • Unilateral Blood Pressure Measurement
  • Heart Rate/Pulse Remotely Controlled
  • Multiple Heart Sounds
  • Assess Pulses (Carotid & Radial)
Vascular Access
  • Sternal/Humeral/Tibial Intraosseous Placement
  • Venipuncture/IV Catheter Placement/Fluid & Blood Infusion
Trauma & Resuscitation
  • Chest Compressions
  • Pelvic Binder Placement

Hemorrhage Management

Features Technical Details
Trauma Scenarios
  • Assess & Treat Traumatic Amputation
  • Assess & Treat Traumatic Open Fractures
  • Assess & Treat Traumatic Closed Fractures
  • Assess & Treat Traumatic Penetrating Groin Injury/Trauma
  • Assess & Treat Traumatic GSW Chest with/without Exit
  • Assess & Treat Traumatic GSW Axillary Junctional Trauma
  • Assess/Treat Entrance/Exit Penetrating Chest Wound
  • Penetrating Trauma Wounds
Bleeding Simulation
  • Assess & Treat Arterial Hemorrhage
  • Assess & Treat Venous Hemorrhage
  • Multiple and Independent Bleeding Sites
  • Remote-Controlled Pulsatile Arterial Bleeding
  • Remote-Controlled Venous Bleeding
Intervention Support
  • Control Bleeding by Direct Pressure/ Pressure Points/ Elevation/Wound Packing/Pressure Bandage/ Tourniquet/ Junctional Tourniquet. Supports all Commercial Tourniquets
System Capacity
  • Blood Reservoir: Male: 3L, Female 1.1L

Neurological and Musculoskeletal Specifications

Features Technical Details
Neurological Status
  • Bilateral Blinking Eyes
  • Bilateral Pupillary Assessment (Normal/Constricted/Dialted)
Musculoskeletal & Trauma
  • Assess and Treat Fractures
  • Assess for Crepitus
  • Apply Cervical Collar

Breathing Specifications

Features Technical Details
Respiration Dynamics
  • Remote-controlled respiratory rate
  • Bilateral and independent chest excursion
Trauma Management
  • Tension Pneumothorax: Corrected by midclavicular and anterior axillary needle decompression
  • Chest Tube: Bilateral chest tube insertion capable
Ventilation Support
  • Support to external ventilation

Urinary and Integumentary

Features Technical Details
Urinary Management
  • Periodic and Responsive Urine Output
  • Sensed Urinary Catheterization Placement
  • Supports Straight and Indwelling Foley Catheters
Gastrointestinal
  • Bowel Sounds: Four Independently Controlled Quadrants (No Sound, Normal, Hypoactive and Hyperactive)
Integumentary (Skin)
  • Assess and Treat Burns

Upgrade Options

Features Technical Details
Hardware Expansion
  • Additional Interchangeable Limbs and Moulage Wounds
Software & Content
  • Additional Clinical and Trauma Scenarios
  • Additional Drug Support Library
  • Additional Premium Real-World Patient Monitor Screens

PCCS Pro FAQs

These are interchangeable, plug-and-play trauma limbs with software designed to automatically adjust to specific limb features.

It is the only trauma simulator to meet all 13 PCC guidelines established by the PCC Work Group for casualty management.

Ready to train like a pro?